6 x XRF Analysis, powder or liquid in cups

$200.00

Bulk Discount
1 - 4 itemsStandard price
5 - 9 items2.5% off
10+ items5.0% off
Category: Brand:

Six samples at 33.33 each, against 50 for a single.

Powders and liquids only, submitted in 32 mm cups. Cups load into the autosampler tray and run as a batch without anyone standing over them, which is why the per sample price is lower.

Solid objects are not covered by this listing. Bars, ingots, castings, cores and parts each need hand loading and alignment, so they go through the single analysis listing at 50 each.

Size limits

32 mm cup, 10 mL maximum, 7 mL recommended minimum. Roughly 10 to 15 g for a dense mineral powder, or 5 to 8 g for a light organic powder. Material must be compatible with polypropylene and must not dissolve, corrode, damage or weaken the cup or its thin retaining film.

Label each cup with an ID, a short material description and its priority elements.

Instrument

Rigaku NEX DE energy dispersive XRF, helium purge. Rowow LLC has no affiliation with, or endorsement by, Rigaku.

Element range

Sodium (Na) through uranium (U).

The light elements Na, Mg, Al, Si, P and S are measured under helium purge and are semi-quantitative. In metal-rich or mineral-rich samples sodium is usually below the reporting limit and magnesium is approximate. If a light element is central to your decision, ask before ordering.

Rough detection limits

Working figures, not certified limits:

  • Mid-range elements (roughly K through Zr) in a light matrix: tens of ppm
  • The same elements in a heavy matrix such as iron, copper or lead rich material: one to several hundred ppm
  • Light elements (Na through S): percent level

Heavier matrices absorb the signal, so the same element reads differently depending on what surrounds it. If you need parts per billion, XRF is the wrong method and you want ICP-MS.

What XRF cannot tell you

  • Nothing below sodium. Carbon, nitrogen, oxygen, fluorine, lithium, beryllium and boron are invisible to any XRF at any price. Oxygen is calculated, never measured.
  • Elements only, not compounds or oxidation states. You get total iron, not Fe(II) against Fe(III), and not magnetite against hematite. Identifying which mineral or compound an element sits in needs XRD.
  • Surface only. Roughly the top 10 to 100 microns. Coatings, plating, oxide, oil and paint dominate the result.
  • One spot, roughly 10 mm across. The result describes that spot, not the average of a heterogeneous sample.

Known hard cases

Some element pairs sit too close together for an energy dispersive detector to separate. The common ones:

  • Vanadium in a titanium-rich sample
  • Chromium alongside vanadium
  • Arsenic alongside lead
  • Cobalt alongside iron
  • Iridium alongside lead. If lead is present, treat any reported iridium as unreliable.

These are reported as screening indications rather than firm numbers. Ask first if one of these pairs is what you need.

How composition is estimated

Composition is estimated from instrument calibration. Absolute values are approximate without matrix-matched standards, and relative comparison between similar samples is more reliable than any single absolute number.

Sample preparation

No preparation is performed here. The sample is loaded and measured as submitted.

Powders should be dry and ground as fine as you can manage, ideally under 75 microns. Grain size directly affects the lighter elements. Coarse, wet or oily samples can be run, but the numbers will be softer. Note it on your order and it will be recorded on the report rather than quietly degrading the result.

Not accepted

Radioactive material, biological or medical samples, explosives or energetic material, compressed gas, and unsealed free liquids. If you are unsure, ask before shipping.

What the results are not for

Results are not certified and Rowow is not an accredited laboratory. They are not suitable for commercial settlement, JORC or NI 43-101 resource reporting, customs declarations, or regulatory compliance. For any of those you need an accredited laboratory.

Deliverable and turnaround

PDF report by email, listing detected elements and estimated composition. Often same day or two business days, though turnaround is not guaranteed and orders run first come, first served.

Before you ship

Read the XRF Analysis Service Terms before shipping anything. They cover the instrument and the status of results, the element range, what the report contains, required labeling and hazard documentation, method limitations, sample preparation, the retest policy, the 7 day holding period, and turnaround.

unit_pricing_measure

1 ct

How do I submit my samples?
After purchase, you will be contacted with submission instructions. Samples must be in SC-3332 sample cup holders (10 mL max). Clearly label each sample with an ID, brief material description, and elements to prioritize. Include hazardous material declarations if applicable.
How long does analysis take?
Turnaround time varies depending on sample volume and current demand. Contact info@rowow.net before ordering if you have a deadline. You will receive a PDF report with elemental composition results.
What elements can be detected?
The Rigaku NEX DE XRF instrument detects elements from Sodium (Na) through Uranium (U). Accuracy varies by element, matrix, and sample preparation. Provide a prioritized list of elements when submitting.
Are the results certified or accredited?
No. Results are not certified, accredited, or otherwise official. This is an in-house analysis service for individual and research access. Results apply only to the submitted sample and specific area/spot tested.
Can I send powder and liquid samples?
Yes. Both powder and liquid samples (up to 10 mL in SC-3332 cups) are accepted. A minimum of 7 mL is recommended for best accuracy. Solid/large objects may also be submitted - see the Single XRF Analysis listing.

DIY Resources

Build your own electrochemical cell using Rowow membranes. Find open-source designs, guides, and parts lists below.

Open-Source Designs on GitHub

Schematics, CAD files, BOM lists, and assembly guides for building electrolysis cells and flow battery systems.

Visit Rowow on GitHub →

Video Tutorial: How to Make Ion Exchange Membranes

Recommended Parts & Supplies

Amazon affiliate links below help support Rowow open-source development:

Affiliate disclosure: As an Amazon Associate, Rowow earns from qualifying purchases.

Community Reviews & Builds

🔬

Be the First to Share Your Build

Content will appear here as people purchase and use these items. Share your setup, photos, and results with the Rowow community.

Share Your Build

Returns Policy

All sales are final. Rowow products are provided strictly for research, development, and testing purposes and are sold AS-IS. We do not accept returns, exchanges, or cancellations for any reason, including change of mind, incompatibility, or dissatisfaction with results.

Damaged or wrong item? If your order arrives damaged in transit or we shipped the wrong item, contact us within 72 hours of delivery at info@rowow.net with photos and your order number for review.

View Full Return & Refund Policy →

Shipping Information

  • International Shipping: We ship worldwide, except to sanctioned or prohibited countries. See the Prohibited Countries List under the Liability Agreement.
  • 💰Shipping Cost: Calculated at checkout based on destination and package weight.
  • Handling Time: Orders may take 2 weeks or longer to process depending on demand and material availability. Contact us at info@rowow.net before ordering if you need urgent delivery confirmation.
  • 📦Carriers: USPS, UPS, and FedEx are available.
  • Brand: Rowow — Custom-made item.
Shopping Cart