RESEARCH / TESTING USE ONLY — NOT CERTIFIED OR APPROVED FOR CONSUMER OR REGULATED APPLICATIONS

This listing is for (1) composite cation exchange membrane sheet, letter size (11 in x 8.5 in). The membrane is a thick, PVC-based composite with fiberglass reinforcement. Due to the fiberglass mix, it is mostly rigid and typically measures ~0.5–3 mm thick (variation expected).

Cutting / handling

Edges should be cut carefully to prevent fraying. Use sharp, quality scissors/box cutter knife and handle the cut edge gently. Avoid tearing or aggressive bending.

Mounting / sealing options

Because the membrane is PVC-based, it can be mounted using methods and materials compatible with PVC, including:

  • Bonding to a PVC frame using compatible adhesives/bonding methods (recommended “safe default” for most builds)

  • Gasket + compression

  • Hot glue, silicone, and other sealants can work, but use caution: ensure compatibility with your electrolyte and any acids/solvents in your system, and avoid overheating/deforming the membrane.

Operating envelope (experimental)

  • Temperature: recommended below 60°C (PVC-based composite).

  • pH / pressure: not rated / unknown — this membrane is sold strictly for experimental research, and the Buyer is responsible for determining compatibility and safe operating limits for their specific chemistry and setup.

Conditioning / first use

The membrane may require initial conditioning (“polarization”) to reach stable performance:

  • Soak in your intended conductive solution prior to first use.

  • Allow current to run through the membrane; in some cases, a higher-than-normal operating voltage may be used briefly to help polarize/condition (user discretion and responsibility, reduce voltage over time or use a fixed amperage power supply).

  • Recommended current density: 50–200 mA/cm², depending on solution conductivity and cell design. Performance and optimal settings vary by electrolyte, geometry, temperature, and operating conditions.

Shipping / storage (IMPORTANT)

Membranes ship hydrated in a wet sealed bag. Keep sealed until ready to use. The membrane can be gently patted dry with a paper towel for handling and sealing, but:

DO NOT ALLOW THE MEMBRANE TO FULLY DRY. Full drying can permanently damage the membrane, causing shrinkage and cracking. Store sealed and hydrated when not in use. Avoid freezing.

Research disclaimer / liability notice

This membrane is provided as-is for research, development, educational, or industrial evaluation only. It is not certified, accredited, or approved for potable water, food contact, medical, life-safety, consumer, or regulatory-compliance applications. The Buyer is solely responsible for safe handling, installation, compatibility testing, operating parameters (including chemical exposure, temperature, pH, and pressure), and lawful use and disposal. No guarantees are made regarding performance, results, durability, or fitness for any particular purpose.

Weight .9 lbs
Dimensions 15 × 12 × 1 in
unit_pricing_measure

1 ct

What size is this membrane?
The membrane is letter-size: 11 x 8.5 inches (same as standard US letter paper). It is thick and rigid due to the PVC/fiberglass composite construction.
How do I cut this membrane to size?
Use a straight edge and a sharp utility knife or rotary cutter on a hard surface. Score firmly and snap, or cut fully through. Avoid tearing, which can fray the fiberglass reinforcement.
Can this fit the V1 Electrolysis Cell?
Yes - this is the same membrane used in the V1 Cation Electrolysis Cell Slide-In Membrane listing. It fits the membrane slot of the V1 cell body, with up to two membranes fitting simultaneously.
What electrolytes is it compatible with?
Compatible with acidic, alkaline, and neutral electrolyte solutions including sulfuric acid, sodium hydroxide, and various salt solutions. For specific compatibility, contact us at info@rowow.net.
Is this for research/testing use only?
Yes. This product is for research, development, and testing purposes only. It is not certified for consumer or regulated applications.

DIY Resources

Build your own electrochemical cell using Rowow membranes. Find open-source designs, guides, and parts lists below.

Open-Source Designs on GitHub

Schematics, CAD files, BOM lists, and assembly guides for building electrolysis cells and flow battery systems.

Visit Rowow on GitHub →

Video Tutorial: How to Make Ion Exchange Membranes

Recommended Parts & Supplies

Amazon affiliate links below help support Rowow open-source development:

Affiliate disclosure: As an Amazon Associate, Rowow earns from qualifying purchases.

Community Reviews & Builds

🔬

Be the First to Share Your Build

Content will appear here as people purchase and use these items. Share your setup, photos, and results with the Rowow community.

Share Your Build

Returns Policy

All sales are final. Rowow products are provided strictly for research, development, and testing purposes and are sold AS-IS. We do not accept returns, exchanges, or cancellations for any reason, including change of mind, incompatibility, or dissatisfaction with results.

Damaged or wrong item? If your order arrives damaged in transit or we shipped the wrong item, contact us within 72 hours of delivery at info@rowow.net with photos and your order number for review.

View Full Return & Refund Policy →

Shipping Information

  • International Shipping: We ship worldwide, except to sanctioned or prohibited countries. See the Prohibited Countries List under the Liability Agreement.
  • 💰Shipping Cost: Calculated at checkout based on destination and package weight.
  • Handling Time: Orders may take 2 weeks or longer to process depending on demand and material availability. Contact us at info@rowow.net before ordering if you need urgent delivery confirmation.
  • 📦Carriers: USPS, UPS, and FedEx are available.
  • Brand: Rowow — Custom-made item.
Shopping Cart